Optical Coherence Tomography
US$48,215.00
- Comprehensive Feature
- High speed & High definition
- Ultra high speed scan efficiency: 250,000 A-scan/s
- AI auxiliary diagnosis
- Stable Performance
Technical Specification | OCT-NV | Advantages | |
| Optical Source | Super Luminescent Diode, 840nm | ||
| Axial Resolution | 5ÎĽm | ||
| Transverse Resolution | 15ÎĽm | ||
| Scan Speed | 250,000 A-scans per second | Fastest speed in industry. User-friendly | |
| Scanning Parameters | Scanning Modes | Retinal, Glaucoma, Anterior Segment | |
| Single-Line Scanning | 6mm | ||
| 3D Scanning Speed | <1 Second | Fastest in industry in the level | |
| A-scan depth | 2mm | ||
| Focus Adjustment | ﹣23D~+17D | ||
| Frame Averaging | Yes | ||
| Frame Scanning Rage | Â 256-4096 A-Scans/Frame | More graphical details compared with Primus 200 | |
| Scanning Line | Â 1024 Points | ||
| Customizable Scan and Measurement | Yes | Allows doctors to have better scan | |
| HD Scanning Line | 4096 A-Scans/Picture | ||
| Scanning Time | Fastest in Industry | ||
| Locating Function | Multiple Locating Functions: Fovea-Center ONH auto-centering | Good for repetitive diagnosing | |
| Fixation | Internal fixation | ||
| Pupil Size requirement | 2mm | ||
| Refractive stromal requirements | Good, even cataract and old patients | ||
| Retinal thickness analysis | YES | ||
| OCT Angiography | YES | ||
| Glaucoma Analysis | Analysis Parameters | RNFL thickness, ONH analysis; GCA analysis | |
| ONH auto-centering | YES | Higher Reliability | |
| Glaucoma Follow-up Analysis | YES | Convenient for patient’s data tracking | |
| Anterior Segment OCT | YES | ||
| Methodology | Spectral Domain OCT | ||


12mm HD Imaging:
â—† Meticulous organizational structure


Diagnose Different Fundus Diseases | HD Single Line Scan:
â—† Wide range scan
â—† HD imaging by 100 times of selective overlay pixels
â—† EDI depth-enhanced Imaging


Macular Area Scan:
â—† 6*6mm area stereoscopic imaging
â—† Macular thickness measuring&analyzing
â—† Comparative analysis with standard
normal person database
â—† Macular automatic centering function


â—† High-resolution visualization of micro vessel morphology in the macular area
â—† Automatically removes projection artifacts to display retinal layered blood vessel images clearly and accurately


Accurate Glaucoma Diagnosis & Follow-up Function:
Ganglion cell analysis
â—† Accurate ganglion cell analysis, detects glaucoma damage earlier
â—† Binocular contrast analysis
â—† Comparative analysis with standard normal person database


Optic Disc Area Structure Scan & Analysis:
â—† Optic disc area structure scan & measure
â—† Nerve fiber layer thickness analysis
â—† Comparative analysis with standard normal person database
â—† Binocular contrast analysis


â—† 16mm single scan bilateral anterior chamber imaging
â—† Specialized Tool for Measurement and Analysis of Anterior Chamber Angle Opening
â—† Non-contact, Rapid Diagnosis and Differentiation of Open/Closed Angle Glaucoma


High Definition Corneal Scanning Analysis:
â—† 12mm corneal scanning range
â—† High-resolution scanning with clear and distinguishable corneal layers
â—† Thickness measurement tool, providing quick and convenient quantitative measurements


Corneal Thickness Measurement & Analysis:
â—† Imaging through Dense Scanning with 24 Crossed Lines
â—† Topographic Map of Corneal Thickness with 9mm Central Diameter and Regional Thickness Analysis
â—† Facilitating Convenient and Accurate Screening for Keratoconus, Refractive Surgery Examinations,
and Other Clinical Diagnostic Reference
Technical Data:


Brand
Ray Vision